Angelus-RFG
INDICATIONS For the support of restorations and prosthetic crowns.
COMPOSITION
- Peeso drills: Stainless steel
- Rubber Stops: Latex
- Template for radiographic measurement: Plastic
- REFORPOST® GLASS FIBER: Glass fiber (80%); pigmented resin (19%), stainless steel filament (1%).
- REFORPOST® CARBON FIBER: Carbon fiber (72%); pigmented resin (22%), stainless steel filament (6%).
TECHNIQUE OF USE
- Select the pin using the template and the periapical x-ray of the tooth;
- Remove some of the root canal filling with heated instruments to the predetermined depth. Allow at least 3 to 5 mm of filling at the root apex;
- Prepare the canal with the drill corresponding to the diameter of the post. Place the post and cut at the desired limit with a diamond drill at high speed under refrigeration;
- Clean the post with alcohol and dry it;
- Apply a layer of silane (SILANO ANGELUS®) and let it dry for 1 minute;
- WARNING: It is not necessary to apply the silane on REFORPOST® CARBON FIBER.
- Apply the ANGELUS® FUSION-DURALINK® CATALYST to the post according to its instructions.
- Clean the canal with the air-water spray and dry it with air and absorbent paper points;
- Etch the canal with ANGELUS® 37% PHOSPHORIC ACID for 15 seconds;
- Rinse and dry with air and absorbent paper points.
- Apply ANGELUS® FUSION-DURALINK® PRIMER in the canal and wait for 1 minute;
- Apply ANGELUS® FUSION-DURALINK® CATALYST according to the instructions. This adhesive requires no curing;
- Spatulate the resinous cement selected* and fill the conduit;
- Put the post in the canal, remove excess of the cement, and wait for the polymerization.
- Auto-adhesive cements eliminate the need for the steps of acid conditioning and adhesive application.
- Perform conditioning and apply an adhesive on the remaining crown and on the post. Build the crown core with composite resin, or with ANGELUS® REFORCORE®. REFORCORE® is a prefabricated glass fiber core.
- USE OF ACCESSORY POSTS IN WEAKENED ROOTS AND WIDE CANALS
- Fill the remaining conduit spaces with accessory posts REFORPIN ANGELUS to reduce the thickness of the cement and better imbrication.
WARNINGS | PRECAUTIONS
- The use of fiber posts is not suitable for extensive rehabilitation and for use in patients with parafunctional habits;
- Prefabricated fiber posts should be used only on teeth with a minimum of 2 mm in dentin height;
- Fiber posts should only be cut with water-refrigerated high-speed diamond burs. Do not use scissors or cutting pliers. Use goggles and a mask to prevent inhalation of particles generated during cutting;
- Fiber posts must be completely covered by the cementing agent or the composite resin.
IMPORTANT: The indication of any post depends on careful evaluation of the quality of endodontic treatment and periapical health.
Packaging:
- 15 posts (5 # 1, 5 # 2 and 5 # 3)
- 1 radiographic guide.